CONSTRUCTIONS FOR ZINC GALVANIZATION
Our company realizes the hot dip galvanization according to the Czech standard EN ISO 14 713
The main principles are:
- to avoid closed corners which could make air pockets and air volumes
- all double plated surfaces should be provided with air gaps and/or openings
- to avoid very narrow slots between some parts of the construction
- to install blow-out openings to locate each vent diagonally against the other one
- the construction should be provided by openings/holes and holders for making the montage of any adjacent parts
- all founded casts made by sand forms must be cleaned by a sand stream prior to their galvanization
- to avoid big metal walls formed by a thin not armored metal sheets which could be deformed during the zinc process
It is absolutely necessary either to avoid any use of closed rooms or to ensure a blow-out holes or drainage of closed slots, otherwise occurs a serious risk of a big explosion !
Recommended sizes of blow-out openings:
|
Diameter of hollow part
in mm
|
Minimal diameter of blow-out opening
in mm |
| < 25 |
8 - 10 |
| 25 - 50 |
12 |
| 50 - 100 |
16 |
| 100 - 150 |
20 |
| > 150 |
25 |
It is convenient to contact management of the mentioned galvanizing factory in case of a treatment of some complicated constructions to agree on the location of blow-out openings in advance.
Hot dip galvanizing
Metal production